ADU · Saratoga County
Can you build an ADU in Corinth, NY?
Village of Corinth has 8 districts. All districts prohibit ADUs. Check your address to confirm the district that applies to your parcel:
What the Corinth code says
The Village of Corinth has no accessory dwelling unit. A second unit comes only as a principal use: in VR-I and VR-II a two-family dwelling takes exactly the same lot, width, yards and coverage as a single-family house.
Conditions the code attaches:
- In SR a two-family dwelling needs the same acre as a single-family house but 150 ft of width rather than 100 ft.
- Multifamily and townhouses in VR-I need at least 15,000 sq ft at 100 ft of width and 40% coverage, plus 2,500 sq ft for each additional unit after the first three.
- A business with residence above is a permitted principal use in VB, on at least 5,000 sq ft with no setbacks and 100% coverage.
- No residential use of any kind is available in the I district.
- Confirm with the Village before assuming any of these routes works as an accessory unit.
What the Corinth code indicates by district
The table below shows how each district treats ADUs, alongside the lot and setback standards that govern a second unit. District boundaries and conditions vary, so treat this as a starting point and confirm the district that applies to your parcel.
| District | Min lot | Setbacks F / S / R | Max height | ADU |
|---|---|---|---|---|
| VR-I Village Residential I | 0.23 ac | 15 / 15 / 10 ft | 40 ft | No |
| VR-II Village Residential II | 0.23 ac | 15 / 15 / 10 ft | 40 ft | No |
| SR Suburban Residential | 1 ac | 40 / 15 / 15 ft | 40 ft | No |
| VB Village Business | 0.11 ac | 0 / 0 / 0 ft | 40 ft | No |
| GC Gateway Corridor | 0.23 ac | 15 / 15 / 15 ft | 40 ft | No |
| SGC Secondary Gateway Corridor | 0.23 ac | 15 / 15 / 15 ft | 40 ft | No |
| I Industrial | 2 ac | 50 / 25 / 25 ft | 40 ft | No |
| EP-NOD East Palmer Neighborhood Overlay | 0.23 ac | 15 / 15 / 10 ft | 40 ft | No |
VR-I Village Residential I - A two-family dwelling is permitted by right on the same standard as a single-family house: 10,000 sq ft, 100 ft of width and 30% coverage, with no extra land, no extra frontage and no permit.
- A multifamily building or a townhouse needs site plan review and 15,000 sq ft on 100 ft of width, with a 25 ft front yard, a 20 ft rear and 40% coverage.
- Above three units, 2,500 sq ft per unit is added to that 15,000 sq ft, so a fourth unit needs 17,500 and a fifth 20,000.
- On a corner lot every street frontage is a front lot line with a full front yard, and the owner and the code enforcement officer pick which remaining yard is side and which is rear (§ 500-12).
- Only one principal use and one principal building are allowed per lot (§ 500-11).
- Both the 40 ft height and the three-storey limit bind (§ 500-13).
- A church, cultural facility, group home or assisted living community, medical clinic or nursing home needs site plan review and 30,000 sq ft on 150 ft of width at 60% coverage.
VR-II Village Residential II - A two-family dwelling and a mobile home are both permitted by right on the same lot, width, yards and coverage as a single-family house. On a corner lot every street frontage is a front lot line with a full front yard on each, so a corner carries two front yards.
- Multifamily and townhouses need 15,000 sq ft on 100 ft of width at 40% coverage, with a 25 ft front and 20 ft rear yard, and 2,500 sq ft per unit after the first 3 units.
- A mobile home is permitted in no other district in the Village.
- Height is capped at both 40 ft and three stories, and buildings over 40 ft are separately subject to Adirondack Park Agency regulation.
- Also on site plan review, in sq ft: 15,000 for a bed-and-breakfast on 150 ft at 60%, and 30,000 for a church, cultural facility, group home, assisted living, clinic or nursing home on 150 ft.
- Only one principal use and building is permitted per lot (§ 500-11).
- On a corner lot the Code Enforcement Officer and the owner choose which remaining yard is the side and which the rear (§ 500-12).
SR Suburban Residential - Only one principal use and building is permitted per lot. On a corner lot every street frontage is a front lot line with a full front yard on each, so a corner carries two front yards.
- Multifamily and townhouses take site plan review on one acre with no per-unit land rule, unlike VR-I and VR-II, which add 2,500 sq ft after the third unit.
- A campground, conference center, educational facility or retirement community needs 5 acres on 150 ft of width, with a 40 ft front, 20 ft rear and 15 ft side yard and 60% coverage.
- A bed-and-breakfast is held to 20% coverage and a church takes a 25 ft front yard rather than 40 ft; both, with a cultural facility and a group home, take site plan review.
- A day-care facility needs a 20 ft rear yard where a dwelling needs 15 ft.
- Height is capped at both 40 ft and three stories, and buildings over 40 ft are separately subject to Adirondack Park Agency regulation.
- On a corner lot the Code Enforcement Officer and the owner choose which remaining yard is the side and which the rear (§ 500-12).
VB Village Business - A business with a residence above is permitted by right on a 5,000 sq ft lot with no site plan review, and a two-family dwelling takes the same lot by site plan review. More than one principal building may stand on a lot with site plan approval.
- With no yards and 100% coverage, the 40 ft and three-story height limit is the only dimensional limit on a building. Buildings over 40 ft also face Adirondack Park Agency regulation.
- A bed-and-breakfast, funeral home, gasoline station or recreation-based business needs site plan review on the 5,000 sq ft lot.
- An auction hall or a bank with a drive-through needs 10,000 sq ft and 100 ft of width rather than 50 ft.
- Multifamily and a retirement community need 15,000 sq ft, and a church or commercial lodging 20,000 sq ft.
GC Gateway Corridor - The figures shown are for a single-family dwelling. A bed-and-breakfast, eating and drinking establishment, gasoline station or commercial lodging needs a 75 ft front, 50 ft rear and 75 ft side yard.
- A veterinary clinic needs 75 ft front, 60 ft rear and 75 ft side yards on 250 ft of width. A church, club or lodge needs 50 ft front and 50 ft side yards.
- Most other commercial uses take a 40 ft front, 20 ft rear and 15 ft side yard at 60% coverage.
- Lot minimums by use: 20,000 sq ft for multifamily, 30,000 for a gasoline station and 40,000 for commercial lodging. A retirement community needs five acres.
- Accessory uses need a 40 ft front, 10 ft rear and 20 ft side yard, deeper in front and wider at the side than for the house itself.
- On a corner lot every street frontage is a front lot line with a full front yard on each (§ 500-12).
- More than one principal building may stand on a lot with site plan approval (§ 500-11).
SGC Secondary Gateway Corridor - A duplex is permitted by right on the same 10,000 sq ft lot as a single-family dwelling, with coverage rising to 40%. More than one principal building may stand on a lot with site plan approval (§ 500-11).
- Commercial lodging is a site plan use needing at least 40,000 sq ft on 300 ft of width, with a 75 ft front, 50 ft rear and 75 ft side yard.
- By site plan review a bed-and-breakfast, cultural or educational facility, office or place of worship needs 10,000 sq ft, and a funeral home, group home or multifamily 20,000 sq ft at 60% coverage.
- A day-care facility is permitted by right at 40% coverage but needs a 40 ft front and 20 ft rear yard.
- On a corner lot every street frontage is a front lot line with a full front yard on each (§ 500-12).
- Height is capped at both 40 ft and three stories, and buildings over 40 ft are separately subject to Adirondack Park Agency regulation.
I Industrial - No dwelling use of any kind is available in this district. Adult entertainment uses and automobile repair need site plan review on at least one acre, but with a 75 ft front yard and 50 ft rear and side yards.
- Manufacturing industry, industry, a warehouse, a research and development facility and a commercial storage unit are permitted by right on the figures shown.
- Only one principal use and building is permitted per lot (§ 500-11).
- On a corner lot every street frontage is a front lot line with a full front yard on each (§ 500-12).
- Height is capped at both 40 ft and three stories, and buildings over 40 ft are separately subject to Adirondack Park Agency regulation.
EP-NOD East Palmer Neighborhood Overlay - Every use in this district needs special use review, and none is available by right or by site plan review alone. A retail or wholesale store is limited to 1,500 sq ft of sales floor area.
- The mixed-use row requires nonresidential on the first floor and multifamily above, and takes 15,000 sq ft on 150 ft of lot width against the district's 10,000 and 100 ft.
- The retail, personal and professional service, and eating and drinking uses are each limited to premises without a drive-through, so a drive-through is not available.
- Only one principal building is permitted per lot (§ 500-11).
- On a corner lot every street frontage is a front lot line with a full front yard on each (§ 500-12).
- Height is capped at both 40 ft and three stories, and buildings over 40 ft are separately subject to Adirondack Park Agency regulation.
ADUs vs. short-term rentals in Corinth
No local short-term-rental law on record - which is not the same as permission for Village of Corinth. The Village of Corinth has no local short-term rental law, and that is not the same as permission. Confirm in writing with the Village before counting on short-stay income. These are separate questions from whether you can build an ADU — a unit you're allowed to add isn't automatically one you're allowed to rent nightly, so check both.
Good to know
- Residential lot minimum0.23–1 ac — an ADU still has to fit the district's lot and setback envelope.
- UtilityNational Grid territory.
- Zoning codeecode360.com/26882407
ADU FAQ — Corinth, NY
Are ADUs allowed in Corinth, NY?
Village of Corinth has 8 districts. All districts prohibit ADUs. Check your address with the free ADU checker, or confirm with the building department.
Do I need a special permit for an ADU in Corinth?
No. No district in Village of Corinth permits an ADU, so there is no permit to apply for. Codes change, so verify with the building department before ruling it out.
Can I use an ADU as a short-term rental in Corinth?
No local short-term-rental law on record - which is not the same as permission for Village of Corinth. ADU occupancy and short-term-rental rules are separate: an ADU you can build isn't automatically one you can rent nightly. Confirm both before you count on STR income.
What an ADU costs to build in Corinth
Permission is one question and budget is another. An 800 sq ft accessory unit here runs roughly $200k–260k at a standard finish, and the per-square-foot rate comes in above a full house because the kitchen, bath, panel and heating plant cost the same either way. See the full cost to build an ADU in Corinth, priced by size.
How we know this
- Sections analyzed
- Ch. 500 Schedule 1 district dimensional standards; accessory use row; two-family, multifamily and business-with-residence-above rows
- Districts confirmed
- 8 of 8 — every mapped district.
- Last reviewed
- Not covered here
- Overlay districts, the zoning map, and any conditions attached to an individual parcel. Size limits and owner-occupancy terms sit in the code section above, not in this summary.
More on Corinth: Full zoning for new construction · ADU build cost · House build cost · ADU rules across Saratoga County · All Saratoga County towns
ADU information for Village of Corinth is compiled from the municipal code (last reviewed 2026-08-01) and provided for decision-support only — not legal or architectural advice. ADU eligibility, size, owner-occupancy and permit conditions vary by district and often carry exceptions; verify with the municipality before relying on any answer. Source: the Offsite / Aldo zoning dataset.